Vista MiniD400 Manuel d'utilisateur Page 19

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 27
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 18
19
5. EVENT SETUP
5.1 ALARM SETUP
5.1.1 ALARM INPUT (ON / OFF): Select ‘ON’ if you want to use alarm input device.
5.1.2 INPUT TYPE: Select alarm input type between ‘Normally Open’ and ‘Normally Close’
NC: NORMAL CLOSE
NO: NORMAL OPEN
5.1.3 ALARM OUTPUT:
ALARM INPUT ALARM OUTPUT
Normally Open Normally Open
A
larm input type is Normal Open.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Open Normally Closed
A
larm input type is Normal Open.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Normally Closed Normally Open
A
larm input type is Normal Close.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Closed Normally Closed
A
larm input type is Normal Close.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Note: In ‘Normal Close’ mode, if an intruder cuts the cable that connects the sensor to the MiniD400, the unit will
start to record automatically. In ‘Normal Open’ mode, if an intruder cuts the cable that connects the sensor to
the MiniD400, the unit will not start to record.
ON
N.O.
ON
1. OFF
LOW
ON
2. OFF
3. OFF
4. OFF
T
IME
Vue de la page 18
1 2 ... 14 15 16 17 18 19 20 21 22 23 24 25 26 27

Commentaires sur ces manuels

Pas de commentaire